Data underlying the publication: Role of adherend material on the fracture of bi-material composite bonded joints

Datacite citation style:
Lopes Fernandes, Romina; Teixeira de Freitas, S. (Sofia); Budzik, M.K. (Michal); Poulis, J.A. (Johannes); Benedictus, R. (Rinze) (2020): Data underlying the publication: Role of adherend material on the fracture of bi-material composite bonded joints. Version 1. 4TU.ResearchData. dataset. https://doi.org/10.4121/uuid:870395b1-92f5-4953-aa5d-aca27ef4bbc2
Other citation styles (APA, Harvard, MLA, Vancouver, Chicago, IEEE) available at Datacite
Dataset
Purpose of the test campaign: the purpose of these experiments was to investigate the effect of material of the adherends on mode I fracture behaviour of bonded joints. The Double Cantilever Beam (DCB) specimens with different adherend material(s) were tested. Test equipment: all tests were performed on a 20 kN tensile test machine. The crack length was measured by means of a Digital Image Correlation (DIC) system or a camera system. The applied force and displacement were measured by the tensile test machine, and also sent as inputs to the Digital Image Correlation (DIC) system or to the camera, in order to facilitate synchronization of the data.
history
  • 2020-07-21 first online, published, posted
publisher
4TU.ResearchData
format
media types: application/vnd.openxmlformats-officedocument.spreadsheetml.sheet, application/zip, text/plain
organizations
TU Delft, Faculty of Aerospace Engineering, Structural Integrity & Composites Group

DATA

files (1)