*** Dataset accompanying the publication: Increasing Solar Panel output with Blue-Green Roofs 
in Water-Circular and Nature Inclusive Urban Development ***

Els van der Roest a,b*, Joris G. W. F. Voeten c, Dirk Gijsbert Cirkel a 
a KWR, Water Research Institute, Groningenhaven 7, 3430 BB Nieuwegein, The Netherlands. 
b Faculty of Civil Engineering and Geosciences, Delft University of Technology, Stevinweg 1, 2638 CN Delft, The Netherlands
c Team Climate Resilience, Wageningen Environmental Research, P.O. Box 47, 6700 AA Wageningen, The Netherlands 
* Correspondence: els.van.der.roest@kwrwater.nl/e.vanderroest@tudelft.nl 


***General Introduction***
This dataset is based on a full-scale research performed on two adjacent apartment buildings in Amsterdam. 
One roof has a bitumen surface with a solar PV system, the other is a blue-green capillary irrigated solar roof with 
grey (shower-) water suppletion, with a constructed wetroof for grey water purification. 
In the research, the solar output of both roofs was measured and compared, including temperature, irradiation and humidity measurements.
 
The dataset is being made public to act as supplementary data for publication(s) and the PhD thesis of Els van der Roest. 
Also, it might be used by other researchers.

This dataset is a result of the TKI project Urban Photosynthesis and is co-financed with PPS funding
from the Topconsortia for Knowledge & Innovation (TKI’s) of the Ministry of Economic Affairs and Climate. 

***Description of the data in this data set***
This dataset contains the data from 2x6 solar panels on two adjacent apartment buildings in Amsterdam. 
On each roof (blue green - BG) and bitumen (Bi), the energy output and back of panel temperature of 6 panels was measured.
Furthermore temperature and relative humidity were measured under 3 panels on each roof, as well as the temperature 
of the roof surface in the shadow of the panels.
On both roofs the temperature, relative humidity and irradiation were measured above the panels (1.5 m height).
Lastly, 2 temperature sensors were placed in the soil of the blue-green roof, and a rain meter was installed.

The dataset covers 5 months, June to October 2022, and includes only day data (hours with solar irradiation).

Further information can be found in the paper: https://dx.doi.org/10.2139/ssrn.4465934 (Preprint version, will be updated after publication)


The column names in the data file are described below:
			Unit			Description
Time			dd-mm-yyyy hh:mm	date within the run period - UTC +1	
Air_Temp_[i]_Avg	degrees C		Air temperature under panel (average over the last hour) 
Air_Temp_150cm_Avg	degrees C		Air temperature 1.5m above the roof surface (average over the last hour) - T_amb in paper
Rain_mm			mm			Total mm of rain over the last hour
RH_[i]_Avg		%			Relative under the panel (average over the last hour)
RH_150cm_Avg		%			Relative humidity 1.5m above the roof surface (average over the last hour)
RSin_MJ_Tot		MJ			Irradiation 1.5 above the roof surface (average over the last hour)
RSin_Raw_mV_Av		mV			Irradiation 1.5 above the roof surface (average over the last hour)
RSin_W_Avg		W			Irradiation 1.5 above the roof surface (average over the last hour)
Soil_Temp_[i]_Avg	degrees C		Temperature of the soil/substrate of the blue-green roof (average over the last hour)
SolarP_Temp_[i]_Avg	degrees C		Temperature of the back side of the panel (average over the last hour)
Surf_Temp_[i]_Avg	degrees C		Temperature of the roof surface in the shade under the panel (average over the last hour)
Surf_Temp_avg		degrees C		Average temperature of three measurements of the roof surface (per roof) - Ts in paper
Solar_P_Temp_avg	degrees C		Average panel temperature of 6 panels (per roof) - Tp in paper
Air_Temp_avg		degrees C		Average air temperature under the panels (per roof)- Ta in paper
RH_avg			%			Average relative humidity of 3 measurements under teh panel (per roof)
P[number] E		Wh			Output of a specific solar panel AC-AH belong to the blue-green roof, BI-BN belong to the bitumen roof
energy_production_avg	Wh			Average energy production of the 6 panels on either the BG or Bi roof per hour
Wind_ms			m/s			Average wind speed over the last hour - weather station Schiphol
hour			hr			Hour of the day 

[i] refers to a certain sensor number
[number]  refers to a panel number
Column names with an underscore _BG refers to the blue-green roof
Column names with an underscore _Bi refers to the bitumen roof