cff-version: 1.2.0 abstract: "Height V-notch above sensor 0.145 m Parent item: Maisbich (Luxemburg), calculated data from discharge meter Q1, 2003-12 to 2008-05 Measuring instrument: Maisbich basin: V-notch discharge meter Q1 Type: Pressure Sensor Keller DCX-4.0, SN 1454 This instrument is based on differential pressure measurement of two absolute sensors. The sensors measure pressure and temperature. Height of V-notch above sensor: hV=0.145m. The discharge is calculated with the rating curve Q=C*(h-hV)^2.5 where C is a calibration constant and h results from the pressure difference (Willem Luxemburg, Martijn Westhoff). Contributor: Durr, E.H.(Eugene)" authors: - family-names: Luxemburg given-names: W.M.J.(Wim) - family-names: van den Dool given-names: Cees-Anton title: "Calculated data from sensor Q1 at Maisbich for month 2006-10" keywords: version: 1 identifiers: - type: doi value: 10.4121/uuid:6208ab59-1c44-47df-9e44-2833af4bd536 license: 4TU General Terms of Use date-released: 2009-10-08