Maisbich (Luxemburg), data from discharge meter Q4 (Qup), 2006-12 and later
Datacite citation style:
Luxemburg, W.M.J.(Wim); Westhoff, M.C.(Martijn) (2011): Maisbich (Luxemburg), data from discharge meter Q4 (Qup), 2006-12 and later. Version 1. 4TU.ResearchData. dataset. https://doi.org/10.4121/uuid:97925264-6e18-442e-8033-7fa02941af9d
Other citation styles (APA, Harvard, MLA, Vancouver, Chicago, IEEE) available at Datacite
Dataset
usage stats
1015
views
1
downloads
geolocation
Maisbich basin: V-notch discharge meter Q4 (Qup)
lat (N): 49.89071
lon (E): 6.04372
view on openstreetmap
licence
4TU General Terms of Use
collection
Measuring instrument:
Maisbich basin: V-notch discharge meter Q4 (Qup)
Type: Van Essen TD-Driver, SN 19613
This instrument measures pressure with one absolute sensor. It also measures temperature.
Height V-notch above sensor: 0.0018m.
Datasets with correction contain the corrected discharge observed at the Vnotch.
The discharge is calculated as Q=Cd*h^2.5
After correcting the logger measurements with hand measured depths we interpolated the difference (dH)
Then we determined the factor Cd with discharge measurements which we also interpolated
The timing of hand measurements can be corrected to better represent the logged values
The last corrections (variable "clean_corr") were made for blocking of the V-notch weir as folows:
z1 represents the last good discharge value after which sedimentation slowly starts blocking the weir
z2 represents the moment when the blocking is max
z3 represents the moment just before cleaning of the weir
z4 represents the moment after cleaning of the weir
The max difference in discharge is Q(z3)-Q(z4)
history
- 2011-09-19 first online, published, posted
publisher
4TU.Centre for Research Data
format
media types: application/x-netcdf
organizations
TU Delft, Faculty of Civil Engineering and Geosciences
DATA
OPeNDAP data service