Data underlying the publication: Concentration-dependent effects of nickel doping on activated carbon biocathodes
doi:10.4121/19248359.v1
The doi above is for this specific version of this dataset, which is currently the latest. Newer versions may be published in the future.
For a link that will always point to the latest version, please use
doi: 10.4121/19248359
doi: 10.4121/19248359
Datacite citation style:
Chatzipanagiotou, Konstantina-Roxani; Jourdin, L.; David P. B. T. B. Strik; Bitter, J. H. (2022): Data underlying the publication: Concentration-dependent effects of nickel doping on activated carbon biocathodes. Version 1. 4TU.ResearchData. dataset. https://doi.org/10.4121/19248359.v1
Other citation styles (APA, Harvard, MLA, Vancouver, Chicago, IEEE) available at Datacite
Dataset
usage stats
1126
views
1
citations
903
downloads
licence
CC BY 4.0
Investigation of the combination of a metal electrocatalyst (nickel nanostructures on activated carbon) with a bio-electrocatalyst (mixed anaerobic microbial consortium) for CO2 electroreduction. Biological and abiotic electrochemical experiments, in duplicate, with 3 types of electrodes: without nickel catalyst, with low nickel loading (0.01% wt.), and with high nickel loading (5% wt.). Data includes current density and charge during chronoamperometry experiments, concentration of liquid and gas compounds, optical density, NH4+ nutrient concentration, pH of catholyte, electron recovery calculations, dissolved metal concentration (measured with ICP), and microbial community composition from planktonic samples (characterized with NGS).
history
- 2022-03-14 first online, published, posted
publisher
4TU.ResearchData
format
Microsoft Excel (.xlsx)
associated peer-reviewed publication
Concentration-dependent effects of nickel doping on activated carbon biocathodes
organizations
Biobased Chemistry and Technology, Wageningen University & Research;Environmental Technology, Wageningen University & Research
DATA
files (6)
- 5,224 bytesMD5:
277a3fcd8a44faf8aa80898fd27974bb
README for DOI 10.4121 slash 19248359.txt - 2,315,023 bytesMD5:
e3386a0a4b58f3936a643b7f776d218f
AC-Ni bio reactor data UPLOAD.xlsx - 2,991,391 bytesMD5:
c9d79e17c51eae8fa9f7dbb2007d9129
AC-Ni gas & abiotic UPLOAD.xlsx - 345,890 bytesMD5:
708cb9d288da580ffdaa329a5fc9a617
AC-Ni ICP UPLOAD.xlsx - 491,456 bytesMD5:
2adcf0b79b3b7b5391a7ed93db320c52
AC-Ni NGS UPLOAD.xlsx - 4,298,123 bytesMD5:
323fd51b5053c819463a966cf043cf37
AC-Ni potentiostat UPLOAD.xlsx -
download all files (zip)
10,447,107 bytes unzipped