Supporting data for Guided wave and mechanical testing of defective thermoplastic composite ultrasonic welds
Datacite citation style:
Carvalho, Pedro (2019): Supporting data for Guided wave and mechanical testing of defective thermoplastic composite ultrasonic welds. Version 1. 4TU.ResearchData. dataset. https://doi.org/10.4121/uuid:190ac321-ad31-456c-919e-564f7e6333ef
Other citation styles (APA, Harvard, MLA, Vancouver, Chicago, IEEE) available at Datacite
Dataset
usage stats
1653
views
1
citations
242
downloads
categories
time coverage
March – April 2018
licence
CC BY-NC 4.0
The data refers to measurements on single-lap joints manufactured by ultrasonic welding (UW) of adherends made of thermoplastic composite material. Three different set of UW process parameters were used to manufacture three different batches of joints. The process parameters were selected such that one of the batches had non-defective welds (reference specimens), and the other two had welds with two types of well-controlled manufacturing defects. The purpose of the study was to understand how ultrasonic guided waves (GWs) interact with different defective weld interfaces.
history
- 2019-01-25 first online, published, posted
publisher
4TU.Centre for Research Data
format
media types: application/pdf, application/x-matlab-data, application/zip, text/csv, text/plain, text/x-matlab
organizations
TU Delft, Faculty of Aerospace Engineering, Department of Aerospace Structure and Materials
DATA
files (1)
- 86,132,051 bytesMD5:
8201d6859deabf219895afe847a65ca0
data.zip -
download all files (zip)