Data underlying the publication "Design and evaluation of a pneumatic actuation unit for a wasp-inspired self-propelled needle"
DOI:10.4121/460d12fa-b29f-40e0-a095-c5109bbaec10.v1
The DOI displayed above is for this specific version of this dataset, which is currently the latest. Newer versions may be published in the future.
For a link that will always point to the latest version, please use
DOI: 10.4121/460d12fa-b29f-40e0-a095-c5109bbaec10
DOI: 10.4121/460d12fa-b29f-40e0-a095-c5109bbaec10
Datacite citation style
Bloemberg, Jette; Hoppener, Bruce; Coolen, Bram; Sakes, Aimée; Paul Breedveld (2024): Data underlying the publication "Design and evaluation of a pneumatic actuation unit for a wasp-inspired self-propelled needle". Version 1. 4TU.ResearchData. dataset. https://doi.org/10.4121/460d12fa-b29f-40e0-a095-c5109bbaec10.v1
Other citation styles (APA, Harvard, MLA, Vancouver, Chicago, IEEE) available at Datacite
Dataset
Supporting information underlying the publication "Design and evaluation of a pneumatic actuation unit for a wasp-inspired self-propelled needle":
S1 Software. Arduino code to control Arduino board in phantom and MRI experiments.
S2 Appendix. Phantom experiment protocol.
S3 Software. MATLAB software to run the phantom experiment data analysis.
S4 Data. Raw data set of the phantom experiment.
S5 Video. Video of the needle moving through gelatin.
S6 Appendix. Magnetic resonance parameters.
S7 Appendix. MRI experiment protocol.
S8 Video. MRI video of the needle moving through tissue.
History
- 2024-07-03 first online, published, posted
Publisher
4TU.ResearchDataFormat
arduino uno (ino), matlab (m), zip, mp4, docxAssociated peer-reviewed publication
Design and evaluation of a pneumatic actuation unit for a wasp-inspired self-propelled needleFunding
- Perspectief programme, Photonics Translational Research – Medical Photonics (MEDPHOT) (grant code 80450) [more info...] NWO-TTW
Organizations
TU Delft, Faculty of Mechanical Engineering, Department of BioMechanical EngineeringDATA
Files (7)
- 1,618 bytesMD5:
0b1ad128df23a914a02721f46454f5c5README.txt - 2,545 bytesMD5:
823c00d1946e3e7c0203320924176eb4S1_Software_Arduino.ino - 22,193 bytesMD5:
eeed5267ed669e40fe96281cf2a85e76S3_SlipPneumaticOvipositorNeedle.m - 1,282,410 bytesMD5:
6dd3292e70972a9934ee5e081b9dce85S4_Data.zip - 26,875,145 bytesMD5:
6c6bc7bad8aec15ea90a65dc0c08ca7eS5_VideoPhantom.mp4 - 3,407,691 bytesMD5:
cd86c941f5e4cc3b70d3150dc67a839aS8_VideoMRI.mp4 - 32,909 bytesMD5:
045519dafeb7aa09f97601ea3b252dcbSupporting information.docx -
download all files (zip)
31,624,511 bytes unzipped