SOWFA simulation setup belonging to the paper: The revised FLORIDyn model: Implementation of heterogeneous flow and the Gaussian wake
doi: 10.4121/20026406
SOWFA setup for a nine turbine wind farm in turbulent wind during a wind direction change.
This simulation is used as a preliminary indicator on how wakes might behave during changing environmental conditions.
The turbines are set up in a 3x3 grid with the initial wind direction coming from 255 deg and then uniformly shifting by -60 deg to 195 deg in a 300 s time frame (from 20600 s to 20900 s). All turbines are 10 MW DTU reference turbines, simulated with an actuator disc.
For more details see the relevant files. OpenFOAM 2.4 was used to run the simulation.
Content
The data set contains the relevant in- and outputs from the simulation and its precursor. This should be sufficient to validate the plots from the related publications and to understand how the simulation was set up.
Naturally, you will need to adapt local paths to your installation if you want to rerun the simulation.
Note
Due to a known bug in SOWFA, the power generated is multiplied twice with the air density. Therefore, to get the actual power generated, divide by 1.225.
- 2022-06-09 first online, published, posted
DATA
- 1,090 bytesMD5:
19633bb44947492742ff9d007ce9f270
README.txt - 5,935,061,624 bytesMD5:
23f17656c331ce2385af59222d4f294b
9TCase.zip - 696,065,626 bytesMD5:
3e1896d22f65a3d937de2a4ed9046446
Precursor Setup.zip -
download all files (zip)
6,631,128,340 bytes unzipped