Data underlying the publication: A realistic arteriovenous dialysis graft model for hemodynamic simulations

doi:10.4121/20131736.v1
The doi above is for this specific version of this dataset, which is currently the latest. Newer versions may be published in the future. For a link that will always point to the latest version, please use
doi: 10.4121/20131736
Datacite citation style:
Sjeng Quicken; Barend M. E. Mees; Niek Zonnebeld; Jan H. M. Tordoir; Wouter Huberts et. al. (2022): Data underlying the publication: A realistic arteriovenous dialysis graft model for hemodynamic simulations. Version 1. 4TU.ResearchData. dataset. https://doi.org/10.4121/20131736.v1
Other citation styles (APA, Harvard, MLA, Vancouver, Chicago, IEEE) available at Datacite
Dataset

This repository contains processed CFD data required to recreate figures 2 and 3 of the publication: A realistic arteriovenous dialysis graft model for hemodynamic simulations. All data is stored in XDMF/H5 format and can be visualized using scientific visualization software such as paraview (https://www.paraview.org/). The 3D geometries used for this study can be extracted from the result files.


The data is structured as follows:


* Simulation: Simulation results root folder

    

    * Realistic: contains all CFD results of the realistic geometry

        

        * flow_metrics: contains all time-averaged derived cfd metrics


            3D representations of the wall shear derived metrics are stored in the files below. For the paper only "OSI", "WSS_MAX" and "TAWSS" are used. Other included metrics include the minimal WSS ("WSS_MIN") and the relative residence time ("RRT")

            * pt01iBlock_wss_metrics.xdmf/h5: (corresponding to the ZF-DB boundary condition in the manuscript)

            * pt01iZCRCZ_wss_metrics.xdmf/h5: (corresponding to the AVCE-DB boundary condition in the manuscript)

            * pt01iZCRCZR_wss_metrics.xdmf/h5: (corresponding to the AVCE-DB boundary condition in the manuscript)


            3D representations of turbulence metrics are stored in the files below. Root-mean-square magnitude of high frequency velocity perturbations are quantified using the data field "TSI"

            * turbulenceBlock.xdmf/h5 (corresponding to the ZF-DB boundary condition in the manuscript)

            * turbulenceZCRCZ.xdmf/h5 (corresponding to the AVCE-DB boundary condition in the manuscript)

            * turbulenceZCRCZR.xdmf/h5 (corresponding to the AVCE-DB boundary condition in the manuscript)


    * Idealized: contains all CFD results of the idealized geometry. Same folder structure as Realistic




history
  • 2022-06-24 first online, published, posted
publisher
4TU.ResearchData
format
Zipped .XDMF and .H5 CFD result files
funding
  • Chemelot InSciTe, grant number BM1.01
  • SURF Cooperative, grant number: muc16272
organizations
TU Eindhoven, Department of Biomedical Engineering

DATA