Measured data from sensor IMD at Westerbork for month 2005-05
Datacite citation style:
Gerrits, A.M.J.(Miriam) (2009): Measured data from sensor IMD at Westerbork for month 2005-05. Version 1. 4TU.ResearchData. dataset. https://doi.org/10.4121/uuid:989cabca-a7a1-4751-a47c-ca3b2db35f00
Other citation styles (APA, Harvard, MLA, Vancouver, Chicago, IEEE) available at Datacite
Dataset
usage stats
1340
views
3
downloads
geolocation
Westerbork interception measurement location
lat (N): 52.91437
lon (E): 6.60536
view on openstreetmap
time coverage
2005-05
licence
4TU General Terms of Use
collection
Parent item:
All data measured by interception measurement device in Westerbork
Measuring instrument:
Westerbork: Interception measurment device
Evaporation measurement.
Area basin 0.36 m2, 2x3 strain gauges: type FLA-6, resistance 120 Ohm.
Valve (< 18 jan 2006): electronic magnetic valve Type: MBMG2Z-1263008-12V. (KOBOLD Instrumentatie BV, Arnhem)
Valve (> 18 jan 2006): electronic magnetic valve (12VDC) Type: MBMG2Z-1264020. Messing 3/4 "(?) (KOBOLD Instrumentatie BV, Arnhem)
Temperature sensor: LM335, output 10 mV/K (Farnell).
history
- 2009-10-08 first online, published, posted
publisher
4TU.Centre for Research Data
format
media types: application/x-netcdf, text/xml
organizations
TU Delft, Faculty of Civil Engineering and Geosciences
contributors
- Durr, E.H.(Eugene)
DATA
OPeNDAP data service